The BUS2SER Paradox EVO RS232 Interface allows you to interface the EVO bus to external systems via a RS232 serial connection.
Product Description:
When used with an EVO Series control panel, the BUS2SER Paradox Interface can also be used as an interface between a home automation system and your control panel. For information on this feature and its related programming sections, refer to the ASCII Protocol Programming Instructions and/or C-Bus Programming Instructions.
Product Features:
- In-field firmware upgradeable via a CONV4USB and WinLoad
- Supports ASCII / C-BUS protocols
- 16 virtual inputs to trigger an action in the EVO control panel based on an event received from the peripheral system using ASCII or C-BUS protocol
- 30 virtual PGMs to trigger an action in the peripheral system using ASCII or CBUS protocol based on an event received from the EVO control panel
- USB port for PC connections
- Provides an interface between an EVO control panel and a third party peripheral system
- Automatically/manually print reports of zones/systems event via printer and/or PC
- Parallel and serial port for printer connections
- Assign to one or more partitions
- 2048 event buffer
Technical Specification:
Serial Port | 1 start bit, 8 data bit, no parity and 1 stop bit (8N1) |
Input Voltage | 9-16 Vdc |
Current Consumption | 60mA maximum |
Serial Port Baud Rates | 2400, 9600, 19200 or 57600 bps |
Event Buffer | 2048 events |
Compatibility | EVO192 and EVOHD control panels |