A fully supervised one-door access control with integrated and secure network communication.
Product Description:
With firmware, functionality, and communication protocols compatible to the IdentivDIGI*TRAC and Mx Controllers, the Mx-1-ME seamlessly integrates with existing systems, retaining credentials, readers, and user databases. Designed for use with uTrust TS readers and secure keypads, Mx-1-ME adds network edge capability to the Identiv enterprise security management ecosystem.
Product Features:
- Fully supervised one-door model with integrated, secure network communication
- Scalable from a single controller to networked multi-site installations
- Connectivity to OSDP (RS-485) or Wiegand readers
- Auxiliary input and relay, high-security supervised alarm inputs, and configurable relay outputs (door or general purpose)
- Wet or dry relay hardware setting
- Multi-microprocessor architecture with dedicated crypto-processor
- Firmware upgrade via Velocity
- Integrated network communication with onboard 10/100/1000 Ethernet IP port
- Integrated hardware encryption with enabled devices
- Special circuitry to protect reader/relay terminals from excessive current draws
- Optional support for wireless lock integration with the MX-1-W license
Technical Specification:
COMMUNICATIONS | |
Serial Interface Ports | Controller to controller:• RS-485 multi-drop protocol (X*NET2, X*NET3)• Up to 4,000 ft (1,200 m) with 22 gauge, 2 pair, stranded, twisted, and shielded |
OSDP Protocol | Controller to reader:• Buzzer, LED, and optional secure OSDP• Single port for entry and exit readers• Up to 4,000 ft (1,200 m) with 18 gauge, 2 pair, stranded, twisted, and shielded |
Wiegand Protocol | Onboard Wiegand:• Industry standard Wiegand• Reader ports: 2 (1 entry port and 1 exit port)• Maximum wiring run: 500 ft (150 m) with 18 gauge, 2 pair, stranded, twisted, overall shield |
FIRMWARE | |
Command and Control Module (CCMx) | • Flash upgradeable• Time zones: 150• Door groups: 128• Control zones: 256• Holiday schedules: 4 (366 days x 2 years)• Daylight savings time adjustment |
SNIB3 | • Flash upgradeable with signed and encrypted firmware• FIPS AES 256 encryption• TLS 1.2 Encryption (Requires Velocity 3.7 SP2 or later)• 10/100/1000 Ethernet (TCP/IPv4 or v6) |
MEMORY | |
Buffers | Standard: 1,500 events and 1,500 alarms |
Credentials | Up to 500,000 |
Memory ProtectionBattery | 10 days for code, setups, clock, and buffers |
PHYSICAL | |
Security | Cover opening tamper switch |
Enclosure | NEMA type with conduit knockouts and removable door |
Dimensions | 14 x 14 x 5.5 in |
Weight | 24 lbs (11 kg) w/ battery |
Expansion Boards (Max 5) | 6 H x 4.25 W x .75 D in |
OperatingTemperature Range | 32° to 140°F (0° to 60°C) |
Relative Humidity | 0 to 90%, non-condensing |
ELECTRICAL | |
OSDP Keypad/ReaderPower (1 Terminal) | 750mA at 12V (up to 2 readers), fused and resettable |
WiegandKeypad/Reader (2Terminals) | 500mA per port @12V, fused and resettable. Note: When the door and AUX relays are configured at 12V/500mA, the max current draw for the Wiegand reader ports combined is limited to 750mA |
Power Supply | AC INPUT 110 -240V, 50-60 Hz, fused. Built-in PSU module generates 5A @ 30V DC for the controller and connected devices |
Standby Batteries | 2 X 12V, 1.3 AH VRLA connected in series included as standard for 24V back up. |
Door Relay | Dry 2A at 30V, Form CWet 250mA @ 24V / 500mA @ 12V |
Auxiliary Relay | Dry 2A at 30V, Form CWet 250mA @ 24V / 500mA @ 12V |
Listings and Approvals | UL 294: Access Control Systems UnitsUL 1076: Proprietary Burglar Alarm Systems |