Hirsch Mx-1-ME Controller: High-Security Access Control

A fully supervised one-door access control with integrated and secure network communication.

Product Description: 

With firmware, functionality, and communication protocols compatible to the IdentivDIGI*TRAC and Mx Controllers, the Mx-1-ME seamlessly integrates with existing systems, retaining credentials, readers, and user databases. Designed for use with uTrust TS readers and secure keypads, Mx-1-ME adds network edge capability to the Identiv enterprise security management ecosystem.

Product Features: 

  • Fully supervised one-door model with integrated, secure network communication
  • Scalable from a single controller to networked multi-site installations
  • Connectivity to OSDP (RS-485) or Wiegand readers
  • Auxiliary input and relay, high-security supervised alarm inputs, and configurable relay outputs (door or general purpose)
  • Wet or dry relay hardware setting
  • Multi-microprocessor architecture with dedicated crypto-processor
  • Firmware upgrade via Velocity
  • Integrated network communication with onboard 10/100/1000 Ethernet IP port
  • Integrated hardware encryption with enabled devices
  • Special circuitry to protect reader/relay terminals from excessive current draws
  • Optional support for wireless lock integration with the MX-1-W license

Technical Specification:

COMMUNICATIONS
Serial Interface PortsController to controller:• RS-485 multi-drop protocol (X*NET2, X*NET3)• Up to 4,000 ft (1,200 m) with 22 gauge, 2 pair, stranded, twisted, and shielded
OSDP ProtocolController to reader:• Buzzer, LED, and optional secure OSDP• Single port for entry and exit readers• Up to 4,000 ft (1,200 m) with 18 gauge, 2 pair, stranded, twisted, and shielded
Wiegand ProtocolOnboard Wiegand:• Industry standard Wiegand• Reader ports: 2 (1 entry port and 1 exit port)• Maximum wiring run: 500 ft (150 m) with 18 gauge, 2 pair, stranded, twisted, overall shield
FIRMWARE
Command and Control Module (CCMx)• Flash upgradeable• Time zones: 150• Door groups: 128• Control zones: 256• Holiday schedules: 4 (366 days x 2 years)• Daylight savings time adjustment
SNIB3• Flash upgradeable with signed and encrypted firmware• FIPS AES 256 encryption• TLS 1.2 Encryption (Requires Velocity 3.7 SP2 or later)• 10/100/1000 Ethernet (TCP/IPv4 or v6)
MEMORY
BuffersStandard: 1,500 events and 1,500 alarms
CredentialsUp to 500,000
Memory ProtectionBattery10 days for code, setups, clock, and buffers
PHYSICAL
SecurityCover opening tamper switch
EnclosureNEMA type with conduit knockouts and removable door
Dimensions14 x 14 x 5.5 in
Weight24 lbs (11 kg) w/ battery
Expansion Boards (Max 5)6 H x 4.25 W x .75 D in
OperatingTemperature Range32° to 140°F (0° to 60°C)
Relative Humidity0 to 90%, non-condensing
ELECTRICAL
OSDP Keypad/ReaderPower (1 Terminal)750mA at 12V (up to 2 readers), fused and resettable
WiegandKeypad/Reader (2Terminals)500mA per port @12V, fused and resettable. Note: When the door and AUX relays are configured at 12V/500mA, the max current draw for the Wiegand reader ports combined is limited to 750mA
Power SupplyAC INPUT 110 -240V, 50-60 Hz, fused. Built-in PSU module generates 5A @ 30V DC for the controller and connected devices
Standby Batteries2 X 12V, 1.3 AH VRLA connected in series included as standard for 24V back up.
Door RelayDry 2A at 30V, Form CWet 250mA @ 24V / 500mA @ 12V
Auxiliary RelayDry 2A at 30V, Form CWet 250mA @ 24V / 500mA @ 12V
Listings and ApprovalsUL 294: Access Control Systems UnitsUL 1076: Proprietary Burglar Alarm Systems