<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>DETNOV Archives - Guard-All</title>
	<atom:link href="https://www.guardall.com.ph/suppliers/detnov/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.guardall.com.ph/suppliers/detnov/</link>
	<description>Electronic Security Systems Inc. &#124; Philippines</description>
	<lastBuildDate>Thu, 07 Nov 2024 05:02:19 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://www.guardall.com.ph/wp-content/uploads/2024/11/cropped-favicon-32x32.png</url>
	<title>DETNOV Archives - Guard-All</title>
	<link>https://www.guardall.com.ph/suppliers/detnov/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>MAD-401 and MAD-402 Series Addressable Modules 1 &#038; 2 Technical Inputs</title>
		<link>https://www.guardall.com.ph/products/mad-401-and-mad-402-series-addressable-modules-1-2-technical-inputs-2/</link>
		
		<dc:creator><![CDATA[Rob]]></dc:creator>
		<pubDate>Thu, 07 Nov 2024 04:50:34 +0000</pubDate>
				<guid isPermaLink="false">https://www.guardall.com.ph//?post_type=products&#038;p=2984</guid>

					<description><![CDATA[<p>A device ideal for the supervision of any signal for fire control panels.&#160; Description: The MAD-401 and MAD-402 modules are ideal for the supervising of any signal which may require supervision through a NC or NO contact (for example, the state of a door or a watertight door, or the monitoring of any type of sensors which provide free contact relay). The MAD-401 and MAD-402 modules take the power supply directly from the loop and assign a number of loop addresses according to the number of inputs available in the module. Product Features: Technical Specifications: MODULE Loop Features Operating Voltage From 22 to 38VDC Quiescent current consumption &#60; 300 μA Alarm current consumption 3 mA Technical input through a NC or NO contact (configurable) CONNECTION 2 x 1,5 mm2twisted and shielded cable to a Z-200 base ENVIRONMENT Operating temperature From -10°C to +70°C Relative humidity 95% without condensation IP Index IP40 TECHNICAL&#160; FEATURES Size&#160; 100 mm x 100 mm x 23 mm Material ABS APPROVALS EN 54-18 and EN 54-17 (only MAD-401-I and MAD-402-I) MAD-401, MAD-402 Certificate number: 0370-CPR-1181 MAD-401-I, MAD-402-I Certificate number : 0370-CPR-1863</p>
<p>The post <a href="https://www.guardall.com.ph/products/mad-401-and-mad-402-series-addressable-modules-1-2-technical-inputs-2/">MAD-401 and MAD-402 Series Addressable Modules 1 &amp; 2 Technical Inputs</a> appeared first on <a href="https://www.guardall.com.ph">Guard-All</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<p>A device ideal for the supervision of any signal for fire control panels.&nbsp;</p>



<p><strong>Description:</strong></p>



<p>The MAD-401 and MAD-402 modules are ideal for the supervising of any signal which may require supervision through a NC or NO contact (for example, the state of a door or a watertight door, or the monitoring of any type of sensors which provide free contact relay). The MAD-401 and MAD-402 modules take the power supply directly from the loop and assign a number of loop addresses according to the number of inputs available in the module.<br></p>



<p><strong>Product Features:</strong></p>



<ul class="wp-block-list">
<li>Simple installation on the wall or fitted into a DIN rail</li>



<li>Non-polarity supported (only MAD-401 and MAD-402)</li>



<li>Addressing through a programmer</li>



<li>Loop-powered device</li>



<li>Connections through removable terminal blocks and simple fitting of the cable</li>



<li>EN 54-18 and EN 54-17 approved<br><br></li>
</ul>



<p><strong>Technical Specifications:</strong></p>



<figure class="wp-block-table"><table class="has-fixed-layout"><tbody><tr><td colspan="2"><strong>MODULE</strong></td></tr><tr><td colspan="2"><strong>Loop Features</strong></td></tr><tr><td><strong>Operating Voltage</strong></td><td>From 22 to 38VDC</td></tr><tr><td><strong>Quiescent current consumption</strong></td><td>&lt; 300 μA</td></tr><tr><td><strong>Alarm current consumption</strong></td><td>3 mA</td></tr><tr><td></td><td>Technical input through a NC or NO contact (configurable)</td></tr><tr><td colspan="2"><strong>CONNECTION</strong></td></tr><tr><td></td><td>2 x 1,5 mm2twisted and shielded cable to a Z-200 base</td></tr><tr><td colspan="2"><strong>ENVIRONMENT</strong></td></tr><tr><td><strong>Operating temperature</strong></td><td>From -10°C to +70°C</td></tr><tr><td><strong>Relative humidity</strong></td><td>95% without condensation</td></tr><tr><td><strong>IP Index</strong></td><td>IP40</td></tr><tr><td colspan="2"><strong>TECHNICAL&nbsp; FEATURES</strong></td></tr><tr><td><strong>Size&nbsp;</strong></td><td>100 mm x 100 mm x 23 mm</td></tr><tr><td><strong>Material</strong></td><td>ABS</td></tr><tr><td colspan="2"><strong>APPROVALS</strong></td></tr><tr><td rowspan="3"></td><td>EN 54-18 and EN 54-17 (only MAD-401-I and MAD-402-I)</td></tr><tr><td>MAD-401, MAD-402 Certificate number: 0370-CPR-1181</td></tr><tr><td>MAD-401-I, MAD-402-I Certificate number : 0370-CPR-1863</td></tr></tbody></table></figure>
<p>The post <a href="https://www.guardall.com.ph/products/mad-401-and-mad-402-series-addressable-modules-1-2-technical-inputs-2/">MAD-401 and MAD-402 Series Addressable Modules 1 &amp; 2 Technical Inputs</a> appeared first on <a href="https://www.guardall.com.ph">Guard-All</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>DOA Series Indicator Light with Buzzer</title>
		<link>https://www.guardall.com.ph/products/doa-series-indicator-light-with-buzzer/</link>
		
		<dc:creator><![CDATA[Rob]]></dc:creator>
		<pubDate>Wed, 30 Oct 2024 06:22:59 +0000</pubDate>
				<guid isPermaLink="false">https://www.guardall.com.ph//?post_type=products&#038;p=2066</guid>

					<description><![CDATA[<p>The DOA series indicator lights are signaling devices and acoustic warning by buzzer. Description: The DOA series indicator lights are signaling devices and acoustic warning by buzzer. Due to their low consumption and high visibility, they are ideal for informing the user about the actions of the extinguishing system, fire detection system and detection of toxic gasses (carbon monoxide). Product Features: Technical Specifications: INDICATOR LIGHT DOA FJ/CPD DOA K DOA K/WP Operating voltage From 10.8 to 28 VDC From 24 to 28 VDC From 24 to 28 VDC Alarm current consumption 110 mA 55 mA 55 mA Volume at 1 m From 81 to 87 dB 91,7 dB 91,7 dB Frequency 3050 Hz 2900 Hz 2900 Hz CONNECTIONS 2 x 1,5 mm2 twisted ENVIRONMENT Operating temperature From -10C to +55°C From -10C to +55°C From -10C to +55°C Relative humidity 95% without condensation 95% without condensation 95% without condensation IP Index IP21C IP21 IP54 PHYSICAL FEATURES Size 320 mm x 140 mm x 68 mm 331 mm x 150 mm x 68 mm 331 mm x 150 mm x 68 mm Material ABS and polycarbonate ABS and polycarbonate ABS and polycarbonate APPROVALS EN 54-3 and EN 54-23 (DOA FJ/CPD only EN 54-3) Certificate number: 1328-CPR-0615&#160; Certificate number: 1328-CPR-0725 Certificate number: 1328-CPR-0726</p>
<p>The post <a href="https://www.guardall.com.ph/products/doa-series-indicator-light-with-buzzer/">DOA Series Indicator Light with Buzzer</a> appeared first on <a href="https://www.guardall.com.ph">Guard-All</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<p>The DOA series indicator lights are signaling devices and acoustic warning by buzzer.</p>



<p><strong>Description:</strong></p>



<p>The DOA series indicator lights are signaling devices and acoustic warning by buzzer. Due to their low consumption and high visibility, they are ideal for informing the user about the actions of the extinguishing system, fire detection system and detection of toxic gasses (carbon monoxide).</p>



<p><strong>Product Features:</strong></p>



<ul class="wp-block-list">
<li>Power supply 24 V</li>



<li>Low current consumption</li>



<li>EN 54-3 and EN 54-23 approved (depends on the model)<br><br></li>
</ul>



<p><strong>Technical Specifications:</strong></p>



<figure class="wp-block-table"><table class="has-fixed-layout"><tbody><tr><td><strong>INDICATOR LIGHT</strong></td><td><strong>DOA FJ/CPD</strong></td><td><strong>DOA K</strong></td><td><strong>DOA K/WP</strong></td></tr><tr><td><strong>Operating voltage</strong></td><td>From 10.8 to 28 VDC</td><td>From 24 to 28 VDC</td><td>From 24 to 28 VDC</td></tr><tr><td><strong>Alarm current consumption</strong></td><td>110 mA</td><td>55 mA</td><td>55 mA</td></tr><tr><td><strong>Volume at 1 m</strong></td><td>From 81 to 87 dB</td><td>91,7 dB</td><td>91,7 dB</td></tr><tr><td><strong>Frequency</strong></td><td>3050 Hz</td><td>2900 Hz</td><td>2900 Hz</td></tr><tr><td colspan="4"><strong>CONNECTIONS</strong></td></tr><tr><td colspan="4">2 x 1,5 mm2 twisted</td></tr><tr><td colspan="4"><strong>ENVIRONMENT</strong></td></tr><tr><td><strong>Operating temperature</strong></td><td>From -10C to +55°C</td><td>From -10C to +55°C</td><td>From -10C to +55°C</td></tr><tr><td><strong>Relative humidity</strong></td><td>95% without condensation</td><td>95% without condensation</td><td>95% without condensation</td></tr><tr><td><strong>IP Index</strong></td><td>IP21C</td><td>IP21</td><td>IP54</td></tr><tr><td colspan="4"><strong>PHYSICAL FEATURES</strong></td></tr><tr><td><strong>Size</strong></td><td>320 mm x 140 mm x 68 mm</td><td>331 mm x 150 mm x 68 mm</td><td>331 mm x 150 mm x 68 mm</td></tr><tr><td><strong>Material</strong></td><td>ABS and polycarbonate</td><td>ABS and polycarbonate</td><td>ABS and polycarbonate</td></tr><tr><td colspan="4"><strong>APPROVALS</strong></td></tr><tr><td></td><td colspan="3"><strong>EN 54-3 and EN 54-23 (DOA FJ/CPD only EN 54-3)</strong></td></tr><tr><td></td><td><strong>Certificate number: 1328-CPR-0615&nbsp;</strong></td><td><strong>Certificate number: 1328-CPR-0725</strong></td><td><strong>Certificate number: 1328-CPR-0726</strong></td></tr></tbody></table></figure>
<p>The post <a href="https://www.guardall.com.ph/products/doa-series-indicator-light-with-buzzer/">DOA Series Indicator Light with Buzzer</a> appeared first on <a href="https://www.guardall.com.ph">Guard-All</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>TRD-100 Expansion Card of 4 Free Voltage Relay Output</title>
		<link>https://www.guardall.com.ph/products/trd-100-expansion-card-of-4-free-voltage-relay-output/</link>
		
		<dc:creator><![CDATA[Rob]]></dc:creator>
		<pubDate>Wed, 30 Oct 2024 06:21:34 +0000</pubDate>
				<guid isPermaLink="false">https://www.guardall.com.ph//?post_type=products&#038;p=2065</guid>

					<description><![CDATA[<p>An expansion card designed to increase the number of relay outputs of DETNOV’s fire control panels. Description: The TRD-100 expansion card has been designed to increase the number of relay outputs of Detnov&#8217;s CCD-100 range of conventional fire control panels. The TRD-100 card provides 4 free contact relay outputs with their three corresponding contacts (common, normally opened, normally closed), which may be used to carry out activations by zone in a conventional system. Technical Specifications: RELAY OUTPUT Maximum load 10A to 30VCC Delay selectable on panel board 0-10 minutes ENVIRONMENT Operating temperature From -5°C to +40°C Relative humidity 95% without condensation</p>
<p>The post <a href="https://www.guardall.com.ph/products/trd-100-expansion-card-of-4-free-voltage-relay-output/">TRD-100 Expansion Card of 4 Free Voltage Relay Output</a> appeared first on <a href="https://www.guardall.com.ph">Guard-All</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<p>An expansion card designed to increase the number of relay outputs of DETNOV’s fire control panels.<br></p>



<p><strong>Description:</strong></p>



<p>The TRD-100 expansion card has been designed to increase the number of relay outputs of Detnov&#8217;s CCD-100 range of conventional fire control panels. The TRD-100 card provides 4 free contact relay outputs with their three corresponding contacts (common, normally opened, normally closed), which may be used to carry out activations by zone in a conventional system.<br></p>



<p><strong>Technical Specifications:</strong></p>



<figure class="wp-block-table"><table class="has-fixed-layout"><tbody><tr><td colspan="2"><strong>RELAY OUTPUT</strong></td></tr><tr><td><strong>Maximum load</strong></td><td>10A to 30VCC</td></tr><tr><td><strong>Delay selectable on panel board</strong></td><td>0-10 minutes</td></tr><tr><td colspan="2"><strong>ENVIRONMENT</strong></td></tr><tr><td><strong>Operating temperature</strong></td><td>From -5°C to +40°C</td></tr><tr><td><strong>Relative humidity</strong></td><td>95% without condensation</td></tr></tbody></table></figure>
<p>The post <a href="https://www.guardall.com.ph/products/trd-100-expansion-card-of-4-free-voltage-relay-output/">TRD-100 Expansion Card of 4 Free Voltage Relay Output</a> appeared first on <a href="https://www.guardall.com.ph">Guard-All</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Clampbell Fire Alarm Bells</title>
		<link>https://www.guardall.com.ph/products/clampbell-fire-alarm-bells/</link>
		
		<dc:creator><![CDATA[Rob]]></dc:creator>
		<pubDate>Wed, 30 Oct 2024 06:20:49 +0000</pubDate>
				<guid isPermaLink="false">https://www.guardall.com.ph//?post_type=products&#038;p=2063</guid>

					<description><![CDATA[<p>An audible alarm that notifies people in case of fire.&#160; Description: Manufactured by Vimpex in the UK, the ClamBell® EN54-3 approved fire bell incorporates traditional and innovative design. The hinged design of ClamBell® means installers benefit from reduced installation time. Once fitted to the wall and wired to the circuit, ClamBell® clicks shut. Low power consumption and good sonorous tone result from use of an aluminum gong which also significantly reduces weight. Product Features: Technical Specifications: 6” (150 mm)Internal &#8211; 24 V dc 6” (150 mm)Internal &#8211; 12 V dc 6” (150 mm)Internal &#8211; 230 V ac 6” (150 mm)Internal &#8211; 120 V ac ShallowBase DeepBase W/PBase ShallowBase DeepBase W/PBase DeepBase W/PBase DeepBase W/PBase Rated Voltage (V) 20.4 &#8211; 27.6 9.6 &#8211; 13.2 207-253 114-126 Rated Current @24 V (mA): 12 12 TBC Starting Voltage (V): 11 5.5 TBC Sound Output dB(A) @1 m (max): 96.0 TBC 96.0 Temperature Range (C°): -10 &#8211; +50 -25 &#8211; +70 -10 &#8211; +50 -25 &#8211; +70 -25 &#8211; +70 -25 &#8211; +70 Humidity Range (%): ≤96 % Weight (g): 378 g 497 g 499 g 378 g 497 g 499 g 497 g 499 g 497 g 499 g Gong Colour: Red/White/Grey Gong Construction: Aluminum IP Rating: IP21C IP33C IP56 Cat2^2 IP21C IP33C IP56 Cat2^2 IP33C IP56 Cat2^2 IP33C IP56 Cat2^2</p>
<p>The post <a href="https://www.guardall.com.ph/products/clampbell-fire-alarm-bells/">Clampbell Fire Alarm Bells</a> appeared first on <a href="https://www.guardall.com.ph">Guard-All</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<p>An audible alarm that notifies people in case of fire.&nbsp;</p>



<p><strong>Description:</strong></p>



<p>Manufactured by Vimpex in the UK, the ClamBell® EN54-3 approved fire bell incorporates traditional and innovative design. The hinged design of ClamBell® means installers benefit from reduced installation time. Once fitted to the wall and wired to the circuit, ClamBell® clicks shut. Low power consumption and good sonorous tone result from use of an aluminum gong which also significantly reduces weight.</p>



<p><strong>Product Features:</strong></p>



<ul class="wp-block-list">
<li>Permanently fitted gong</li>



<li>Specifically designed weatherproof back box</li>



<li>Mounting options for European, Asian and US style installations</li>



<li>Slick and modern looking</li>



<li>Fully customized pad printed branding</li>



<li>Strobell EN-23 VAD option which integrates ClamBell and VAD for unique combined unit will be available soon<br></li>
</ul>



<p><strong>Technical Specifications:</strong></p>



<figure class="wp-block-table"><table class="has-fixed-layout"><tbody><tr><td></td><td colspan="3"><strong>6” (150 mm)</strong><strong>Internal &#8211; 24 V dc</strong></td><td colspan="3"><strong>6” (150 mm)</strong><strong>Internal &#8211; 12 V dc</strong></td><td colspan="2"><strong>6” (150 mm)</strong><strong>Internal &#8211; 230 V ac</strong></td><td colspan="2"><strong>6” (150 mm)</strong><strong>Internal &#8211; 120 V ac</strong></td></tr><tr><td></td><td><strong>Shallow</strong><strong>Base</strong></td><td><strong>Deep</strong><strong>Base</strong></td><td><strong>W/P</strong><strong>Base</strong></td><td><strong>Shallow</strong><strong>Base</strong></td><td><strong>Deep</strong><strong>Base</strong></td><td><strong>W/P</strong><strong>Base</strong></td><td><strong>Deep</strong><strong>Base</strong></td><td><strong>W/P</strong><strong>Base</strong></td><td><strong>Deep</strong><strong>Base</strong></td><td><strong>W/P</strong><strong>Base</strong></td></tr><tr><td><strong>Rated Voltage (V)</strong></td><td colspan="3">20.4 &#8211; 27.6</td><td colspan="3">9.6 &#8211; 13.2</td><td colspan="2">207-253</td><td colspan="2">114-126</td></tr><tr><td><strong>Rated Current @24 V (mA):</strong></td><td colspan="3">12</td><td colspan="3">12</td><td colspan="4">TBC</td></tr><tr><td><strong>Starting Voltage (V):</strong></td><td colspan="3">11</td><td colspan="3">5.5</td><td colspan="4">TBC</td></tr><tr><td><strong>Sound Output dB(A) @1 m (max):</strong></td><td colspan="3">96.0</td><td colspan="3">TBC</td><td colspan="4">96.0</td></tr><tr><td><strong>Temperature Range (C°):</strong></td><td>-10 &#8211; +50</td><td colspan="2">-25 &#8211; +70</td><td>-10 &#8211; +50</td><td colspan="2">-25 &#8211; +70</td><td colspan="2">-25 &#8211; +70</td><td colspan="2">-25 &#8211; +70</td></tr><tr><td><strong>Humidity Range (%):</strong></td><td colspan="10">≤96 %</td></tr><tr><td><strong>Weight (g):</strong></td><td>378 g</td><td>497 g</td><td>499 g</td><td>378 g</td><td>497 g</td><td>499 g</td><td>497 g</td><td>499 g</td><td>497 g</td><td>499 g</td></tr><tr><td><strong>Gong Colour:</strong></td><td colspan="10">Red/White/Grey</td></tr><tr><td><strong>Gong Construction:</strong></td><td colspan="10">Aluminum</td></tr><tr><td><strong>IP Rating:</strong></td><td>IP21C</td><td>IP33C</td><td>IP56 Cat2^2</td><td>IP21C</td><td>IP33C</td><td>IP56 Cat2^2</td><td>IP33C</td><td>IP56 Cat2^2</td><td>IP33C</td><td>IP56 Cat2^2</td></tr></tbody></table></figure>
<p>The post <a href="https://www.guardall.com.ph/products/clampbell-fire-alarm-bells/">Clampbell Fire Alarm Bells</a> appeared first on <a href="https://www.guardall.com.ph">Guard-All</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>DOTD-230 Conventional Dual Heat &#038; Smoke Detector</title>
		<link>https://www.guardall.com.ph/products/dotd-230-conventional-dual-heat-smoke-detector/</link>
		
		<dc:creator><![CDATA[Rob]]></dc:creator>
		<pubDate>Wed, 30 Oct 2024 06:20:18 +0000</pubDate>
				<guid isPermaLink="false">https://www.guardall.com.ph//?post_type=products&#038;p=2062</guid>

					<description><![CDATA[<p>Designed to detect both heat and smoke signals, allowing for early detection of fire. Description: Detnov’s complete range of 200 series detectors allow reliable fire detection thanks to its advanced analysis technology. Depending on the risk to be protected, you will have to choose the topology of the sensor of the detector, you can choose between: optical, thermal, thermovelocimetric or the combination of said sensors. Detnov’s fire detector has been developed to ensure a quick reaction to fires, meeting the highest quality standards and certification required in the market. A unique reliability when detecting and protecting installations to reduce false alarms, being suitable for the most demanding applications. Product Features: Technical Specifications: DETECTOR Operating Voltage From 9 to 38VDC Quiescent current consumption &#60; 100 μA Alarm current consumption &#60; 100 mA CONNECTIONS 2 x 1,5 mm2twisted cable to a Z-200 base ENVIRONMENT Operating temperature From -10°C to +70°C Relative humidity 95% without condensation IP Index IP20 PHYSICAL FEATURES Head (height x Ø): 42 mm x 100 mm Base (height x Ø): 5 mm x 100 mm Material: ABS APPROVALS EN54-5 and EN54-7 Certificate number: 0370-CPR-2006</p>
<p>The post <a href="https://www.guardall.com.ph/products/dotd-230-conventional-dual-heat-smoke-detector/">DOTD-230 Conventional Dual Heat &amp; Smoke Detector</a> appeared first on <a href="https://www.guardall.com.ph">Guard-All</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<p>Designed to detect both heat and smoke signals, allowing for early detection of fire.</p>



<p><strong>Description:</strong></p>



<p>Detnov’s complete range of 200 series detectors allow reliable fire detection thanks to its advanced analysis technology. Depending on the risk to be protected, you will have to choose the topology of the sensor of the detector, you can choose between: optical, thermal, thermovelocimetric or the combination of said sensors. Detnov’s fire detector has been developed to ensure a quick reaction to fires, meeting the highest quality standards and certification required in the market. A unique reliability when detecting and protecting installations to reduce false alarms, being suitable for the most demanding applications.</p>



<p><strong>Product Features:</strong></p>



<ul class="wp-block-list">
<li>Elegant design and low profile</li>



<li>Dirtiness compensation</li>



<li>Dirtiness and insect protection</li>



<li>Rise-of-rate function</li>



<li>58 oC static alarm function</li>



<li>Two-wire connection without polarity</li>



<li>Remote indicator port</li>



<li>Compatible with any conventional control panel</li>



<li>EN 54-5 and EN 54-7 approved<br></li>
</ul>



<p><strong>Technical Specifications:</strong></p>



<figure class="wp-block-table"><table class="has-fixed-layout"><tbody><tr><td colspan="2"><strong>DETECTOR</strong></td></tr><tr><td><strong>Operating Voltage</strong></td><td>From 9 to 38VDC</td></tr><tr><td><strong>Quiescent current consumption</strong></td><td>&lt; 100 μA</td></tr><tr><td><strong>Alarm current consumption</strong></td><td>&lt; 100 mA</td></tr><tr><td colspan="2"><strong>CONNECTIONS</strong></td></tr><tr><td></td><td>2 x 1,5 mm2twisted cable to a Z-200 base</td></tr><tr><td colspan="2"><strong>ENVIRONMENT</strong></td></tr><tr><td><strong>Operating temperature</strong></td><td>From -10°C to +70°C</td></tr><tr><td><strong>Relative humidity</strong></td><td>95% without condensation</td></tr><tr><td><strong>IP Index</strong></td><td>IP20</td></tr><tr><td colspan="2"><strong>PHYSICAL FEATURES</strong></td></tr><tr><td><strong>Head (height x Ø):</strong></td><td>42 mm x 100 mm</td></tr><tr><td><strong>Base (height x Ø):</strong></td><td>5 mm x 100 mm</td></tr><tr><td><strong>Material:</strong></td><td>ABS</td></tr><tr><td colspan="2"><strong>APPROVALS</strong></td></tr><tr><td></td><td>EN54-5 and EN54-7</td></tr><tr><td></td><td>Certificate number: 0370-CPR-2006</td></tr></tbody></table></figure>
<p>The post <a href="https://www.guardall.com.ph/products/dotd-230-conventional-dual-heat-smoke-detector/">DOTD-230 Conventional Dual Heat &amp; Smoke Detector</a> appeared first on <a href="https://www.guardall.com.ph">Guard-All</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>CCD-102 Conventional Control Panel Series</title>
		<link>https://www.guardall.com.ph/products/ccd-102-conventional-control-panel-series/</link>
		
		<dc:creator><![CDATA[Rob]]></dc:creator>
		<pubDate>Wed, 30 Oct 2024 06:18:43 +0000</pubDate>
				<guid isPermaLink="false">https://www.guardall.com.ph//?post_type=products&#038;p=2059</guid>

					<description><![CDATA[<p>A fire control panel ideal for small and medium installations.&#160; Description: The range of conventional fire detection control panels of Detnov CCD-100 series have been certified according to EN 54-2, EN 54-4 and EN 54-13 to cover all the requirements of small and medium installations. This range of fire control panels is made up of 4 models and it offers 1, 2, 8 and 12 zones. The common features to the whole range include: the discrimination between manual call point alarm and detector alarm, relay outputs for alarm status and fault status, 2 monitored sounder outputs, 24V auxiliary power output, 24V resettable power output and a configurable input. It also allows to connect optional cards: relay cards, supervised sounder cards and communication cards to allow remote control and integration with other systems. Product Features: Technical Specifications: CONTROL PANEL&#160; Power supply 90-264VAC 50/60 Hz Battery capacity 2 x 7.5 Ah Zones Max. alarm current consumption: 82 mAMax. quiescent current consumption: 3.5 mAMax. devices per zone: 32 detectors / 10 MCPMax. cable resistance per zone: 44 Ω Sounder outputs Maximum load: 500 mA per outputDelay selectable on board: 0 &#8211; 10 minutes Free contact relay outputs 10A to 30VCC 24V auxiliary output: 500 mA (1) 24V resettable output: Maximum load: 500 mA (1)Replacement time:&#160; 5 seconds ENVIRONMENT Operating temperature From -5°C to +40°C Relative humidity 95% without condensation IP Index IP30 PHYSICAL FEATURES Size 439 mm x 268 mm x 112 mm Weight (without batteries) 1,9 kg APPROVALS EN 54-2, EN 54-4 and EN 54-13 Certificate number: 0370-CPR-3149&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;PR-1811-064</p>
<p>The post <a href="https://www.guardall.com.ph/products/ccd-102-conventional-control-panel-series/">CCD-102 Conventional Control Panel Series</a> appeared first on <a href="https://www.guardall.com.ph">Guard-All</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<p>A fire control panel ideal for small and medium installations.&nbsp;</p>



<p><strong>Description:</strong></p>



<p>The range of conventional fire detection control panels of Detnov CCD-100 series have been certified according to EN 54-2, EN 54-4 and EN 54-13 to cover all the requirements of small and medium installations. This range of fire control panels is made up of 4 models and it offers 1, 2, 8 and 12 zones. The common features to the whole range include: the discrimination between manual call point alarm and detector alarm, relay outputs for alarm status and fault status, 2 monitored sounder outputs, 24V auxiliary power output, 24V resettable power output and a configurable input. It also allows to connect optional cards: relay cards, supervised sounder cards and communication cards to allow remote control and integration with other systems.</p>



<p><strong>Product Features:</strong></p>



<ul class="wp-block-list">
<li>2, 4, 8 and 12 zones models</li>



<li>Alarm status relay output</li>



<li>Fault status relay output</li>



<li>2 supervised sounder outputs (500 mA each output)</li>



<li>Sounder delay settings on motherboard</li>



<li>24V auxiliary power output (500 mA (1))</li>



<li>24V resettable power output (500 mA (1))</li>



<li>Configurable external input</li>



<li>Test mode with auto-reset function</li>



<li>Multilingual keyboard</li>



<li>ABS plastic case, can be fitted into the wall (optional)</li>



<li>Optional supervised sounders expansion card</li>



<li>Optional free contact relay expansion card</li>



<li>Optional communication expansion card</li>



<li>EN 54-2, EN 54-4 and EN 54-13 approved<br></li>
</ul>



<p><strong>Technical Specifications:</strong></p>



<figure class="wp-block-table"><table class="has-fixed-layout"><tbody><tr><td colspan="2"><strong>CONTROL PANEL&nbsp;</strong></td></tr><tr><td><strong>Power supply</strong></td><td>90-264VAC 50/60 Hz</td></tr><tr><td><strong>Battery capacity</strong></td><td>2 x 7.5 Ah</td></tr><tr><td><strong>Zones</strong></td><td>Max. alarm current consumption: 82 mAMax. quiescent current consumption: 3.5 mAMax. devices per zone: 32 detectors / 10 MCPMax. cable resistance per zone: 44 Ω</td></tr><tr><td><strong>Sounder outputs</strong></td><td>Maximum load: 500 mA per outputDelay selectable on board: 0 &#8211; 10 minutes</td></tr><tr><td><strong>Free contact relay outputs</strong></td><td>10A to 30VCC</td></tr><tr><td><strong>24V auxiliary output:</strong></td><td>500 mA (1)</td></tr><tr><td><strong>24V resettable output:</strong></td><td>Maximum load: 500 mA (1)Replacement time:&nbsp; 5 seconds</td></tr><tr><td colspan="2"><strong>ENVIRONMENT</strong></td></tr><tr><td><strong>Operating temperature</strong></td><td>From -5°C to +40°C</td></tr><tr><td><strong>Relative humidity</strong></td><td>95% without condensation</td></tr><tr><td><strong>IP Index</strong></td><td>IP30</td></tr><tr><td colspan="2"><strong>PHYSICAL FEATURES</strong></td></tr><tr><td><strong>Size</strong></td><td>439 mm x 268 mm x 112 mm</td></tr><tr><td><strong>Weight (without batteries)</strong></td><td>1,9 kg</td></tr><tr><td colspan="2"><strong>APPROVALS</strong></td></tr><tr><td></td><td>EN 54-2, EN 54-4 and EN 54-13</td></tr><tr><td></td><td>Certificate number: 0370-CPR-3149&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;PR-1811-064</td></tr></tbody></table></figure>
<p>The post <a href="https://www.guardall.com.ph/products/ccd-102-conventional-control-panel-series/">CCD-102 Conventional Control Panel Series</a> appeared first on <a href="https://www.guardall.com.ph">Guard-All</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>TED-151-2PE Multi-Purpose Communication Card</title>
		<link>https://www.guardall.com.ph/products/ted-151-2pe-multi-purpose-communication-card/</link>
		
		<dc:creator><![CDATA[Rob]]></dc:creator>
		<pubDate>Wed, 30 Oct 2024 06:16:39 +0000</pubDate>
				<guid isPermaLink="false">https://www.guardall.com.ph//?post_type=products&#038;p=2058</guid>

					<description><![CDATA[<p>A multi-purpose communication card compatible with conventional control panels.&#160; Description: The TED-151-2PE multi-purpose communication card is compatible with conventional CCD-100 control panels and CAD-150 analogue control panels. It provides the integrator, installer or maintainer with various connectivity options in a single communication card. Product Features: Technical Specifications: CONNECTIONS Wired 2 x 1,5 mm2 twisted and shielded cable ENVIRONMENT Operating temperature From -5°C to +40°C Relative humidity 95% without condensation COMPATIBILITY CAD-150 control panels from version 2.83 CCD-100 control panels date of manufacture after January 2016</p>
<p>The post <a href="https://www.guardall.com.ph/products/ted-151-2pe-multi-purpose-communication-card/">TED-151-2PE Multi-Purpose Communication Card</a> appeared first on <a href="https://www.guardall.com.ph">Guard-All</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<p>A multi-purpose communication card compatible with conventional control panels.&nbsp;</p>



<p><strong>Description:</strong></p>



<p>The TED-151-2PE multi-purpose communication card is compatible with conventional CCD-100 control panels and CAD-150 analogue control panels. It provides the integrator, installer or maintainer with various connectivity options in a single communication card.</p>



<p><strong>Product Features:</strong></p>



<ul class="wp-block-list">
<li>Resettable manual call point</li>



<li>Includes a key for maintenance test<br></li>
</ul>



<p><strong>Technical Specifications:</strong></p>



<figure class="wp-block-table"><table class="has-fixed-layout"><tbody><tr><td colspan="2"><strong>CONNECTIONS</strong></td></tr><tr><td><strong>Wired</strong></td><td>2 x 1,5 mm2 twisted and shielded cable</td></tr><tr><td colspan="2"><strong>ENVIRONMENT</strong></td></tr><tr><td><strong>Operating temperature</strong></td><td>From -5°C to +40°C</td></tr><tr><td><strong>Relative humidity</strong></td><td>95% without condensation</td></tr><tr><td colspan="2"><strong>COMPATIBILITY</strong></td></tr><tr><td><strong>CAD-150 control panels</strong></td><td>from version 2.83</td></tr><tr><td><strong>CCD-100 control panels</strong></td><td>date of manufacture after January 2016</td></tr></tbody></table></figure>
<p>The post <a href="https://www.guardall.com.ph/products/ted-151-2pe-multi-purpose-communication-card/">TED-151-2PE Multi-Purpose Communication Card</a> appeared first on <a href="https://www.guardall.com.ph">Guard-All</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>RP-GS1 Conventional Manual Call Point</title>
		<link>https://www.guardall.com.ph/products/rp-gs1-conventional-manual-call-point/</link>
		
		<dc:creator><![CDATA[Rob]]></dc:creator>
		<pubDate>Wed, 30 Oct 2024 06:14:53 +0000</pubDate>
				<guid isPermaLink="false">https://www.guardall.com.ph//?post_type=products&#038;p=2052</guid>

					<description><![CDATA[<p>A resettable manual call point that allows the immediate evacuation in case of fire. Description: The conventional manual call point RP-GS1 is designed to be used as part of the evacuation system in fire protection installations. The manual call points use a patented mechanism that provides a real action, glass breaking sensation, in its activation. An indicator (yellow and black) is displayed at the top of the window when activated. It rearms with a key and is ready to be used immediately, while offering the user the benefits and environmental advantages of an operating device with replenishment to the state without using crystals. Product Features: Technical Specifications: MANUAL CALL POINT Operating voltage From 12 to 24 VDC Quiescent current consumption &#60;100 μA Alarm current consumption &#60;100 mA CONNECTIONS 2 x 1,5 mm2 twisted and shielded cable ENVIRONMENT Operating temperature From -10°C to + 50°C Relative humidity 95% without condensation IP Index IP30 PHYSICAL FEATURES Size 98 mm x 98 mm x 48 mm Material ABS</p>
<p>The post <a href="https://www.guardall.com.ph/products/rp-gs1-conventional-manual-call-point/">RP-GS1 Conventional Manual Call Point</a> appeared first on <a href="https://www.guardall.com.ph">Guard-All</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<p>A resettable manual call point that allows the immediate evacuation in case of fire.</p>



<p><strong>Description:</strong></p>



<p>The conventional manual call point RP-GS1 is designed to be used as part of the evacuation system in fire protection installations. The manual call points use a patented mechanism that provides a real action, glass breaking sensation, in its activation. An indicator (yellow and black) is displayed at the top of the window when activated. It rearms with a key and is ready to be used immediately, while offering the user the benefits and environmental advantages of an operating device with replenishment to the state without using crystals.</p>



<p><strong>Product Features:</strong></p>



<ul class="wp-block-list">
<li>Resettable manual call point</li>



<li>Includes a key for maintenance test<br></li>
</ul>



<p><strong>Technical Specifications:</strong></p>



<figure class="wp-block-table"><table class="has-fixed-layout"><tbody><tr><td colspan="2"><strong>MANUAL CALL POINT</strong></td></tr><tr><td><strong>Operating voltage</strong></td><td>From 12 to 24 VDC</td></tr><tr><td><strong>Quiescent current consumption</strong></td><td>&lt;100 μA</td></tr><tr><td><strong>Alarm current consumption</strong></td><td>&lt;100 mA</td></tr><tr><td colspan="2"><strong>CONNECTIONS</strong></td></tr><tr><td></td><td>2 x 1,5 mm2 twisted and shielded cable</td></tr><tr><td colspan="2"><strong>ENVIRONMENT</strong></td></tr><tr><td><strong>Operating temperature</strong></td><td>From -10°C to + 50°C</td></tr><tr><td><strong>Relative humidity</strong></td><td>95% without condensation</td></tr><tr><td><strong>IP Index</strong></td><td>IP30</td></tr><tr><td colspan="2"><strong>PHYSICAL FEATURES</strong></td></tr><tr><td><strong>Size</strong></td><td>98 mm x 98 mm x 48 mm</td></tr><tr><td><strong>Material</strong></td><td>ABS</td></tr></tbody></table></figure>
<p>The post <a href="https://www.guardall.com.ph/products/rp-gs1-conventional-manual-call-point/">RP-GS1 Conventional Manual Call Point</a> appeared first on <a href="https://www.guardall.com.ph">Guard-All</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>PED-221/PED 231 Conventional Beacon Series</title>
		<link>https://www.guardall.com.ph/products/ped-221-ped-231-conventional-beacon-series/</link>
		
		<dc:creator><![CDATA[Rob]]></dc:creator>
		<pubDate>Wed, 30 Oct 2024 06:14:03 +0000</pubDate>
				<guid isPermaLink="false">https://www.guardall.com.ph//?post_type=products&#038;p=2051</guid>

					<description><![CDATA[<p>An audible and visible alarm notification compatible with DETNOV control panels. Description: The PED-2X1 series beacons are conventional beacons compatible with Detnov’s conventional control panels and addressable sounder modules MAD-43X, in addition to most conventional power plants on the market. Beacons of the PED-2X1 series are certified according EN 54-23. This product range is designed for use with conventional and analog fire detection systems. Product Features: Technical Specifications: BEACON Operating voltage From 18 to 30 VDC Current consumption at 24 V From 25 to 40 mA, depending on the tone Flash coverage ceiling installation C-3-8 Flash coverage wall installation W-2.4-8 CONNECTIONS 2 x 1,5 mm2 twisted ENVIRONMENT Operating temperature From -20°C&#160; to +70°C Relative humidity 95% without condensation IP Index PED-221C and PED-231C: IP21CPED-221W and PED-231W: IP33C PHYSICAL FEATURES Material ABS APPROVALS EN 54-23 Certificate number: 0370-CPR-2966</p>
<p>The post <a href="https://www.guardall.com.ph/products/ped-221-ped-231-conventional-beacon-series/">PED-221/PED 231 Conventional Beacon Series</a> appeared first on <a href="https://www.guardall.com.ph">Guard-All</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<p>An audible and visible alarm notification compatible with DETNOV control panels.</p>



<p><strong>Description:</strong></p>



<p>The PED-2X1 series beacons are conventional beacons compatible with Detnov’s conventional control panels and addressable sounder modules MAD-43X, in addition to most conventional power plants on the market. Beacons of the PED-2X1 series are certified according EN 54-23. This product range is designed for use with conventional and analog fire detection systems.</p>



<p><strong>Product Features:</strong></p>



<ul class="wp-block-list">
<li>Compatible with Detnov&#8217;s conventional control panels and addressable sounder modules</li>



<li>Low current consumption and highly efficient</li>



<li>Suitable for indoor use</li>



<li>Easy installation with base</li>



<li>Approved EN 54-23<br></li>
</ul>



<p><strong>Technical Specifications:</strong></p>



<figure class="wp-block-table"><table class="has-fixed-layout"><tbody><tr><td colspan="2"><strong>BEACON</strong></td></tr><tr><td><strong>Operating voltage</strong></td><td>From 18 to 30 VDC</td></tr><tr><td><strong>Current consumption at 24 V</strong></td><td>From 25 to 40 mA, depending on the tone</td></tr><tr><td><strong>Flash coverage ceiling installation</strong></td><td>C-3-8</td></tr><tr><td><strong>Flash coverage wall installation</strong></td><td>W-2.4-8</td></tr><tr><td colspan="2"><strong>CONNECTIONS</strong></td></tr><tr><td></td><td>2 x 1,5 mm2 twisted</td></tr><tr><td colspan="2"><strong>ENVIRONMENT</strong></td></tr><tr><td><strong>Operating temperature</strong></td><td>From -20°C&nbsp; to +70°C</td></tr><tr><td><strong>Relative humidity</strong></td><td>95% without condensation</td></tr><tr><td><strong>IP Index</strong></td><td>PED-221C and PED-231C: IP21CPED-221W and PED-231W: IP33C</td></tr><tr><td colspan="2"><strong>PHYSICAL FEATURES</strong></td></tr><tr><td><strong>Material</strong></td><td>ABS</td></tr><tr><td colspan="2"><strong>APPROVALS</strong></td></tr><tr><td rowspan="2"></td><td>EN 54-23</td></tr><tr><td>Certificate number: 0370-CPR-2966</td></tr></tbody></table></figure>
<p>The post <a href="https://www.guardall.com.ph/products/ped-221-ped-231-conventional-beacon-series/">PED-221/PED 231 Conventional Beacon Series</a> appeared first on <a href="https://www.guardall.com.ph">Guard-All</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>TUL 500EN Monitored Power Supply 24V/5A</title>
		<link>https://www.guardall.com.ph/products/tul-500en-monitored-power-supply-24v-5a/</link>
		
		<dc:creator><![CDATA[Rob]]></dc:creator>
		<pubDate>Wed, 30 Oct 2024 06:12:39 +0000</pubDate>
				<guid isPermaLink="false">https://www.guardall.com.ph//?post_type=products&#038;p=2044</guid>

					<description><![CDATA[<p>A 24V auxiliary power supply for large and small installations. Description: Monitored 27.6 V and 5 A switched power supply. Microprocessor controlled with constant monitoring of the power supply and automatic disconnection in case of failure. Certified EN 54-4 and EN 12101. Limited current switching, microcontroller monitoring circuit and automatic reset electronic fuses, with metal cab capable of housing batteries up to 17 Ah. Product Features: Technical Specifications: POWER SUPPLY Power supply 220 &#8211; 240 VAC Output voltage 20 &#8211; 30 VDC Output current 5 A BATTERIES 2 x 12 V &#8211; 17 Ah ENVIRONMENT Operating temperature From -5°C to +40°C Relative humidity 95% without condensation IP Index IP30 PHYSICAL FEATURES Size 310 mm x 373 mm x 175 mm Weight (without batteries) 5,6 kg CERTIFICATIONS EN 54-4 and EN 12101-10 Certificate number: 1293-CPR-0587</p>
<p>The post <a href="https://www.guardall.com.ph/products/tul-500en-monitored-power-supply-24v-5a/">TUL 500EN Monitored Power Supply 24V/5A</a> appeared first on <a href="https://www.guardall.com.ph">Guard-All</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<p>A 24V auxiliary power supply for large and small installations.</p>



<p><strong>Description:</strong></p>



<p>Monitored 27.6 V and 5 A switched power supply. Microprocessor controlled with constant monitoring of the power supply and automatic disconnection in case of failure. Certified EN 54-4 and EN 12101. Limited current switching, microcontroller monitoring circuit and automatic reset electronic fuses, with metal cab capable of housing batteries up to 17 Ah.</p>



<p><strong>Product Features:</strong></p>



<ul class="wp-block-list">
<li>Free contact relay output for fault</li>



<li>Capacity of 2 batteries of 12 V up to 17 Ah</li>



<li>LEDS status indicators:</li>
</ul>



<ul class="wp-block-list">
<li>&nbsp;Broken fuses</li>



<li>High battery voltage</li>



<li>Low battery voltage</li>



<li>Main power supply status</li>



<li>No battery recharge</li>



<li>Disconnected battery</li>



<li> High battery resistance<br><br></li>
</ul>



<p><strong>Technical Specifications:</strong></p>



<figure class="wp-block-table"><table class="has-fixed-layout"><tbody><tr><td colspan="2"><strong>POWER SUPPLY</strong></td></tr><tr><td><strong>Power supply</strong></td><td>220 &#8211; 240 VAC</td></tr><tr><td><strong>Output voltage</strong></td><td>20 &#8211; 30 VDC</td></tr><tr><td><strong>Output current</strong></td><td>5 A</td></tr><tr><td colspan="2"><strong>BATTERIES</strong></td></tr><tr><td></td><td>2 x 12 V &#8211; 17 Ah</td></tr><tr><td colspan="2"><strong>ENVIRONMENT</strong></td></tr><tr><td><strong>Operating temperature</strong></td><td>From -5°C to +40°C</td></tr><tr><td><strong>Relative humidity</strong></td><td>95% without condensation</td></tr><tr><td><strong>IP Index</strong></td><td>IP30</td></tr><tr><td colspan="2"><strong>PHYSICAL FEATURES</strong></td></tr><tr><td><strong>Size</strong></td><td>310 mm x 373 mm x 175 mm</td></tr><tr><td><strong>Weight (without batteries)</strong></td><td>5,6 kg</td></tr><tr><td colspan="2"><strong>CERTIFICATIONS</strong></td></tr><tr><td rowspan="2"></td><td>EN 54-4 and EN 12101-10</td></tr><tr><td>Certificate number: 1293-CPR-0587</td></tr></tbody></table></figure>
<p>The post <a href="https://www.guardall.com.ph/products/tul-500en-monitored-power-supply-24v-5a/">TUL 500EN Monitored Power Supply 24V/5A</a> appeared first on <a href="https://www.guardall.com.ph">Guard-All</a>.</p>